Metal Roof Panels
 

Metal Wall Panels
 

Trim Specialties
 

Distribution Materials
 


 
   MRS System 2500





   
 
  • ASTM E1592, E1646, E1680 Tested
  • U.L. 580 Class 90 Certified
  • Ideal for Low Slope Conditions in Commercial or Residential
  • Single or Double-Locked to Ensure a Water-Tight, Integral Design
  • Available in 2" Profile
  • Can be Formed Using 22/24 Gauge Steel and .032/.040 Aluminum
  • Optional Sealant in Female Leg
 
Technical Data
Product Data Sheet
Flashing Details
Product Submittal
UL 580 Class 90
Specs
Watertightness Warranty
Finish Warranty
Color Chart
Seamer Rental/Info
 
     
    Product Data  
 

Materials
12" to 18" O.C.
22/24 ga.
.032 aluminum /.040 aluminum

Panel Features
Flat/Smooth
Striations - Recommended
Stress Ribs
Curved/Radius
Optional Sealant in Female Leg

Requirements
Panel can be installed on Solid Substrate or Open Framing
Ice & Water Shield or Synthetic Underlayment
Minimum Roof Pitch: 1/2" on 12"

Finish
Kynar 500® or Hylar 5000®
Two-Coat Fluropolymer

Single-Lock MRS System 2500
MRS System 2500 Panels are factory-formed to specified lengths and field seamed to a 90º lock. MRS System 2500 panels are available in 12"- 18" widths, in either 22/24 ga or .032/.040 aluminum.



Double-Lock MRS System 2500

MRS System 2500 Panels are factory-formed to specified lengths and field seamed to a 180º lock. MRS System 2500 panels are available in 12"- 18" widths, in either 22/24 ga or .032/.040 aluminum.



Radius MRS System 2500
MRS System 2500 panels can be curved at the factory or on the job site depending on the radius and length of the panel.

UL 580 Class 90 Certified
MRS System 2500 panel carries a UL 90 classification over solid substrates and open framing. Solid substrates include Plywood, OSB, Rigid Insulation, Gypsum Board etc. (UL Construction No. 90, 176, 180, 238, 238A)

Structural Performance
MRS System 2500 panel was tested and observed to meet the performance requirements of the ASTM E1592 for structural performance of metal roof and siding systems.

Air and Water Infiltration
MRS System 2500 panel meets the performance requirements of the ASTM E1646 Air Infiltration test and the & ASTM E1680 Water Penetration test.

  LEED Credits

LEED
If applicable Metal Roofing Systems, Inc. can provide LEED Information when requested. For information on state and local tax initiatives, please go to USGBC Government Resources page.

LEED: SS Credit 7.2 Heat Island Effect: Roof
Requirement: Roofing materials having a Solar Reflectance Index (SRI) equal to or greater than the values below for a minimum of 75% of the roof surface.

Low-Sloped Roof (<=2:12): SRI must be >= 78% (2 colors available)
Steep-Sloped Roof (>=2:12): SRI must be >= 29% (29 or more colors available)

LEED: MR Credit 4.1 Recycled Content
Our material contains the following recycled content:

Galvanized Steel: Recycled scrap represents some 31% of the finished product.
23% of this is Post-Consumer
8% of this is Pre-Consumer

Aluminum Products: Recycled scrap represents some 88% of the finished product.
35% of this is Post-Consumer
53% of this is Pre-Consumer

LEED: MR Credit 5.1 Regional Materials
To qualify the materials being used on the building must have been extracted, havested, or recovered, as well as manufactured, within 500 miles of the project site for a minimum of 10% of the total materials value.

Please contact Metal Roofing Systems to find out if your project will qualify for this LEED credit.

 
     
 
 
© 2012 Metal Roofing Systems